48089 Fremont Blvd
Fremont, CA 94538
(510) 623-9600
www.loadstarsensors.com
DI-100
16-Bit Digital Load Cell Interface
User's Guide
Copyright © 2010 Loadstar Sensors, Inc.
, All Rights Reserved.
Vista de pagina 0
1 2 3 4 5 6 ... 18 19

Indice de contenidos

Pagina 1 - (510) 623-9600

48089 Fremont Blvd Fremont, CA 94538 (510) 623-9600 www.loadstarsensors.com DI-100 16-Bit Digital Load Cell Interface User's Guide Cop

Pagina 2

DI-100 User's Guide Page: 10 / 19 P/N : 033-02205-Rev2 • Attach the plastic base and use the tie-wrap to secure the load cell cable. • Att

Pagina 3

DI-100 User's Guide Page: 11 / 19 P/N : 033-02205-Rev2 3.2 Install Virtual COM Port Drivers The DI-100 may be accessed either through PC’s

Pagina 4

DI-100 User's Guide Page: 12 / 19 P/N : 033-02205-Rev2 3.5 DI-100 Initial Setup DI-100 purchased with a load cell If you have purchased a l

Pagina 5

DI-100 User's Guide Page: 13 / 19 P/N : 033-02205-Rev2 4 CALIBRATING THE DI-100 Please ensure the UNIT and LC (load capacity) commands are en

Pagina 6 - 1 INTRODUCTION

DI-100 User's Guide Page: 14 / 19 P/N : 033-02205-Rev2 4.3 2-Point Calibration Two-Point Calibration is recommended if calibrated weights ar

Pagina 7 - 2 MODULE DETAILS

DI-100 User's Guide Page: 15 / 19 P/N : 033-02205-Rev2 5 DI-100 COMMAND SUMMARY Please note the commands are not case sensitive. All alphabet

Pagina 8 - P/N : 033-02205-Rev2

DI-100 User's Guide Page: 16 / 19 P/N : 033-02205-Rev2 5.1.4 TARE © Function: Tares, or sets the display ZERO value. Summary: When this

Pagina 9

DI-100 User's Guide Page: 17 / 19 P/N : 033-02205-Rev2 5.1.8 W © Function: Displays the current weight Summary: Displays the measured w

Pagina 10 - DI-100 User's Guide

DI-100 User's Guide Page: 18 / 19 P/N : 033-02205-Rev2 5.1.12 SETTINGS © Function: Returns all current setting values Summary: Displays

Pagina 11

DI-100 User's Guide Page: 19 / 19 P/N : 033-02205-Rev2 6 DI-100 TECHNICAL SPECIFICATIONS Performance Resolution 16-Bit A/D Update Speed

Pagina 12 - 3.5 DI-100 Initial Setup

DI-100 User's Guide Page: 2 / 19 P/N : 033-02205-Rev2 Notes © Copyright 2010 Loadstar Sensors Inc, Fremont, CA 94538. All Rights Reserved. N

Pagina 13 - 4 CALIBRATING THE DI-100

DI-100 User's Guide Page: 3 / 19 P/N : 033-02205-Rev2 WARNING 1. Do not use the DI-100 with the cover, or part of the cover removed or loose

Pagina 14 - 4.3 2-Point Calibration

DI-100 User's Guide Page: 4 / 19 P/N : 033-02205-Rev2 The WEEE directive has been transposed into each EU member state’s legislation and so t

Pagina 15 - 5 DI-100 COMMAND SUMMARY

DI-100 User's Guide Page: 5 / 19 P/N : 033-02205-Rev2 Table of Contents 1 INTRODUCTION ...

Pagina 16 - TARE ©

DI-100 User's Guide Page: 6 / 19 P/N : 033-02205-Rev2 1 INTRODUCTION The DI-100 is a 16-Bit Analog-to-Digital Load Cell Interface. It convert

Pagina 17 - 5.1.11 RC ©

DI-100 User's Guide Page: 7 / 19 P/N : 033-02205-Rev2 2 MODULE DETAILS 2.1 External DI-100 Connection Figure 1: Load Cell

Pagina 18 - SETTINGS ©

DI-100 User's Guide Page: 8 / 19 P/N : 033-02205-Rev2 2.2 DI-100 Mechanical Dimensions

Pagina 19 - TECHNICAL SPECIFICATIONS

DI-100 User's Guide Page: 9 / 19 P/N : 033-02205-Rev2 3 STEP BY STEP OPERATING GUIDE 3.1 Attach the Load Cell to the DI-100 If you have ord

Comentarios a estos manuales

Sin comentarios